Ramp allows you to keep the air pressure low when you are trying to fall asleep. Ramp is a comfort feature on all M Series devices. Note: If C-Flex is not enabled on your device, talk to your doctor or home care provider about activating it. Press the stop/start button to save your setting and return to the mail menu.
Encore pro 2 software plus#
Use the C-Flex or plus and minus buttons to increase or decrease the setting. A screen with three C-Flex settings will appear. Press the right arrow to scroll to the C-Flex settings page. You may also change the C-Flex setting using the control buttons and display screen. You can try other settings by simply pressing the C-Flex button on the front of your device. Your device should be set up with a preset C-Flex setting. With three C-Flex settings, you have the ability to select a greater or lesser degree of pressure relief that is right for you. The amount of pressure relief is based on your breathing pattern and your C-Flex setting. Respironics has developed unique product features to make positive airway pressure more comfortable to use, such as C-Flex, ramp, humidification, and Comfort Series masks.Ĭ-Flex lowers the pressure at the beginning of exhalation when many people find therapy most uncomfortable. If your plan does not meet your mask replacement needs, talk to your home healthcare provider. As an informed healthcare consumer, you should be aware of the mask replacement benefits under your healthcare plan. Replace the mask if the cushion becomes hardened or if any parts become damaged.Įven by following these tips, the natural oils in your face will interact with the mask, and over time, the mask will lose its seal. Wash your face thoroughly before using your mask.ģ. Wash the mask in warm water with a mild soap and air dry no need to disassemble the mask. Below you will find the three easy steps to keeping a clean mask:ġ. All masks in the Comfort Series can be cleaned in the same manner.
Encore pro 2 software Pc#
Insert the CD into the CD-ROM drove of the PC.For older REMstar machines with Encore SmartCards, a USB SmartCard reader (part number 1014352) or PCMCIA SmartCard reader (part number 1014353) is required to copy therpay data from the SmartCard to your computer. SD card reader, USB SmartCard reader, or PCMCIA SmartCard reader to copy therapy data from the SD card or SmartCard to your computerĪn SD card reader for PR System One CPAP machines is required to copy therapy data from the PR System One CPAP machine to the EncoreViewer 2.0 software.800圆00 (minimum) resolution video adapter and monitor 1024 x 768 or higher resolution video adapter and monitor are recommended.USB port, keyboard, and Microsoft mouse or compatible pointing device.20 GB hard drive with at least 1 GB of available space.128 MB of system memory (minimum) or the minimum required by the operating system 256 MB of system memory is recommended.
Encore pro 2 software 64 Bit#
Pentium 133 MHz 32 bit (x86) processor (minimum) or the minimum required by the operating system Pentium 300 MHz 32 bit (x86) processor or better is recommended EncoreViewer 2.0 is not compatible with 64 bit processors.Windows compatible computer running Windows 2000 SP4, Windows XP Home or Professional SP2 or later, Windows Vista Home or Business SP1 or later, Windows 7 Home or Professional, or Windows Server 2003 SP2 or later.
Encore pro 2 software pro#
This software does not modify or delete data on the Encore Pro SmartCard.įor assistance in interpreting any of the data represented by this software, please see your doctor or clinician. Encore Viewer can be used to analyze data from the SmartCard or SD card used in your Respironics REMstar legacy, M Series, and PR System One CPAP machines.Įncore Viewer software supports multiple users, so spouses who both use CPAP machines can track their therapy separately.ĮncoreViewer is a valuable tool for use by end users (patients) using Respironics sleep therapy devices to view their compliance and therapy information.
![encore pro 2 software encore pro 2 software](https://i.ytimg.com/vi/o3Uk0Fegrs0/maxresdefault.jpg)
![encore pro 2 software encore pro 2 software](https://aprendomania.com/wp-content/uploads/2021/12/Encore-sin-reconocer-el-archivo-m2v-en-la-version-NTSC.png)
Use Encore Viewer and a SmartCard to view and print the therapy data generated from your Respironics sleep therapy device.
![encore pro 2 software encore pro 2 software](https://s1.manualzz.com/store/data/002561000_3-e85ca2f936ded750b2dbb913273c20cb.png)
Support for PR System One CPAP devices and their SD cards.Support for Windows Vista and Windows 7 (32 bit and 64 bit versions).EncoreViewer 2.1 is basically the same as EncoreViewer 1.0 and 2.0 except for the following new features:
![encore pro 2 software encore pro 2 software](https://s1.manualzz.com/store/data/002719972_1-cfcdc402287351c4496b317554263202.png)
Read our article that covers EncoreViewer 1.0. No more printing and scanning required! Read our article about EncoreViewer 2.0, which has the same general functionality as 2.1.
Encore pro 2 software pdf#
New Version 2.1 with 64-bit operating system support and added support for the newer System One REMstar 60 Series machines.ĮncoreViewer 2.1 exports to PDF in seconds.